Specifications

Initializing the Access Server
6-6
Using the DIAGNOSE Option with INITIALIZE
Using the DIAGNOSE option with INITIALIZE enables you to test the access
server hardware. You can specify three types of tests as described in the
INITIALIZE DIAGNOSE Option Tests.
The following example shows the DIAGNOSE option with INITIALIZE:
Local> INITIALIZE DIAGNOSE FULL
This command initializes the access server in the default mode and performs an
extended test.
INITIALIZE DIAGNOSE Option Tests
The following table shows the tests that are available as part of the INITIALIZE
DIAGNOSE option:
Specifying the DISABLE OPTION with INITIALIZE
Using the DISABLE option with INITIALIZE loads the software image, but
disables the use of the CONNECT command and the AUTOCONNECT function.
The following command shows how to use this option:
Local> INITIALIZE DISABLE
Test Performs
Brief Internal self-test only.
Full Extended test including in-depth memory test
Normal (Default) Standard self-test.