Specifications
Managing Dial Services
22-8
Verifying Dialer Script Configuration
Use the SHOW PORT n command to verify any changes you make to dialer script
assignments for a port. The change appears in the Dialer Script field of the
display.
Example: Show New Port Configuration
The following example shows the display after using the CHANGE PORT n
DIALER SCRIPT command to change the dialer script from Generic_14400 to
dickens:
Local> CHANGE PORT 2 DIALER SCRIPT dickens
Local> SHOW PORT 2
Port 2: Server: user10_DS700-16
Character Size: 8 Input Speed: 57600
Flow Control: XON Output Speed: 57600
Parity: None Signal Control: Enabled
Stop Bits: Dynamic Signal Select: CTS-DSR-RTS-DTR
Access: Dynamic Local Switch: None
Backwards Switch: None Name: PORT_2
Break: Local Session Limit: 4
Forwards Switch: None Type: Ansi
Default Protocol: DIAL Default Menu: None
Dialer Script: dickens
Preferred Service: CALL_HOME
Authorized Groups: 0
(Current) Groups: 0
Enabled Characteristics:
Autoconnect, Autoprompt, Broadcast, DSRlogout, Failover,
Inactivity Logout, Input Flow Control, Lock, Loss Notification,
Message Codes, Output Flow Control, PPP, SLIP, Verification
Local>