User`s guide
FRAME RELAY CONFIGURATION
Local Management User’s Guide B-11
The following information must be supplied to the service provider.
• LMI type: Q.933-A
The line configuration information shown in Table B-3 must be supplied by the service provider.
WPIM-E1 Physical Configuration
Begin the WPIM-E1 configuration by accessing the WAN Physical Configuration screen through
Local Management (Figure B-1). Proceed with the following steps:
1. Use the arrow keys to highlight the [WPIM] field at the bottom of the screen. Press the
SPACEBAR to select the WPIM being configured, then press ENTER.
2. Use the arrow keys to highlight the MgrType. Select either FR Pto MP (Frame Relay Point to
Multipoint) or FR PtoP (Frame Relay Point to Point) using the SPACE bar.
3. Use the arrow keys to highlight Timeslot View. Press the SPACEBAR to select New, then
press ENTER. The cursor moves to Timeslot #2 of the Timeslot Configuration Table.
4. Insert an interface number (see NOTE on page B-6) into every timeslot being used. Type the
number, press ENTER, then use the arrow keys to highlight the next timeslot field. Exit this
field by using the arrow keys. The cursor automatically moves to the E1 Line Coding field.
5. Use the arrow keys to highlight E1 Line Coding. Press the SPACEBAR to select HDB3 or
AMI.
6. Use the arrow keys to highlight E1 Frame Type. Press the SPACEBAR to select E1 or
E1-CRC.
7. Use the arrow keys to highlight E1 Tx Clock Source. Press the SPACEBAR to select Local
(no clock source provided by telephone company) or Loop (clock source provided by telephone
company).
Table B-3 Telco Configuration Information
Configuration Information Required By
Customer
Information Supplied By Service Provider
Line Coding HDB3 or AMI
Frame Type E1 or E1-CRC
Clock Source Loop Timing or Local Timing
DSO’s (Timeslots) Timeslots being used for each end of the circuit