User`s guide

Configuration: Call Backup
Local Management User’s Guide 2-37
Proceed with the following steps:
1. Use the arrow keys to highlight the [WPIM X] field at the bottom of the screen. Press the
SPACE bar to select the WPIM number of the HSIM or CyberSWITCH being configured, then
press ENTER. Typically the backup HSIM or CyberSWITCH will be installed in slot 2 of the
host platform.
2. Use the arrow keys to highlight the MgrType. Press the SPACE bar to select ISDN BRI, then
press ENTER.
3. Use the arrow keys to highlight the SAVE command, then press ENTER. The message “Save
Done” displays and Local Management saves the changes to memory. The message “REBOOT
IN PROGRESS......” will also display, and the host platform will automatically reboot.
NOTE
The MAX VC value associated with a physical WAN interface is set to a default value
based on the number of possible ports available and the protocol manager selected. If
more PVCs/DLCIs exist than the default MAX VC value will allow, the MAX VCs may
be changed.