User`s guide

USER’S GUIDE
514 CyberSWITCH
LMI State
The condition of the LMI link. Possible settings for this item are WAIT FULL STATUS (S1),
WAIT T391 TIMEOUT (S2), and WAIT LIV STATUS (S3). The possible settings are
defined as follows:
WAIT FULL STATUS
The LMI state entered when the local frame relay software has transmitted a STATUS
ENQUIRY message requesting a FULL REPORT STATUS message.
WAIT T391 TIMEOUT
The LMI state entered when the local frame relay software has received a STATUS message
from the network in response to a previous STATUS ENQUIRY and has restarted the T391
timer. (The T391 parameter is the configured Link Integrity Verification Timer.)
WAIT LIV STATUS
The LMI state entered when the local frame relay software has transmitted a STATUS
ENQUIRY message requesting a LINK INTEGRITY VERIFICATION STATUS message.
LMI Error State
Current LMI alarm condition. When this item is TRUE, the LMI alarm is on, and all associated
PVCs are unavailable. When this item is FALSE, the alarm condition is clear.
LMI DLCI
DLCI value associated with the LMI link. This is the DLCI value contained in all LMI messages
and varies according to the LMI format in effect. Note that this is not user configurable.
# LMI Frames Received
Number of frames received on the LMI link.
# Good LMI Frames Received
The number of valid LMI frames received during the last N391 period. This count is reset after
each N391 events. (The N391 parameter is the configured Full Status Enquiry Polling Count.)
# Errored LMI Frames Received
Number of invalid or errored LMI frames received during the last N391 period. This count is
reset when N392 is reached. (The N391 parameter is the configured Full Status Enquiry Polling
Count, and the N392 parameter is the configured Error Threshold Count.)
Unknown DLCI list
List of all unknown DLCIs which have been referenced by either STATUS messages or CLLM
messages. This information is helpful in finding and solving problems on the Frame Relay
Access. In particular, the DLCI list is maintained within the code to identify all DLCIs for which
the network has knowledge, but which are not currently configured. This list is updated when
unknown DLCIs are noted through the LMI FULL REPORT STATUS messages, or through
CLLM messages.
fr dbg level <level>
Displays or sets the current debug level for frame relay. If the level parameter is not specified,
then the current debug level is displayed. The debug level corresponds to an internal variable
that controls how much information is written to the system log as frame relay events occur.
Possible settings for this parameter are 0 through 2, with 0 being the least informative and 2
being the most informative.