The problem is that the pages are being cached in Netscape. This has been
resolved by changing the pages so that they are not cached.
Alarm Manager is crashing intermittently and no core file is being generated.
A bad alarm node is in the table which causes the sorting code to compare bad
data and therefore crash. The bad alarm node is in the table because an
update occurred with both an ADD and a MODIFY. The same could occur if a
REMOVE and a MODIFY came in on the same update. This has been resolved
by making sure the bad data does not get in the table and by adding
additional error checking to the sorting code to guard against crashes like this
in the future.
When suppressing secondary alarms in AlarmWeb it cores. The
"showSecondaryCount" preference is not being registered for in Web Alarm
View because it is not used or needed. However, this preference is being
checked when filtering out suppressed alarms. The preference is being
retrieved and a test is being done to insure it is registered; then it is accessed.
Since it was not registered for in Web Alarm View, the value being retrieved is
NULL and hence the crash. This has been resolved by checking to see if the
preference was registered.
Over several days, Web AlarmView will consume memory until it crashes.
This was resolved by keeping a list of the event nodes used in creating the
historyDataList. This solution only affects users of the history API.
(Also refer to the Notes on corrected anomalies, on Page 5-12.)
SPECTRUM_5.0rev1.P46
This patch number was not used.
SPECTRUM_5.0rev1.P47
Included in P48 and P51.
(Also refer to the Notes on corrected anomalies, on Page 5-12.)
SPECTRUM_5.0rev1.P48
Included in P51.
(Also refer to the Notes on corrected anomalies, on Page 5-12.)
SPECTRUM_5.0rev1.P49
After running Distributed Find across SpectroSERVER landscapes, the
chassis view of the SS6000 and SS9000 boards will not launch in the
landscape to which the user is connected. The problem is that when the
Distributed Find View is launched, it uses the landscape of the server where
the find is being done, instead of the landscape where the SS9000/SS6000
device is actually modeled. The resolution was to the use the model handle of
the SS6000 and SS9000 as the landscape handle.
ADISC does not discover SS6000 devices properly. The problem is that all of
the boards in the chassis do not know about each other across the backplane.