Specifications

MMS2 Software Characteristics Software Release Notice for 5.0rev1
4-6 CS2 and MMS2
6E132-25 (CtRemoteApp)
1. The ds1 Alarms Circuit Configuration view and the DS3 Extensions view
contain ??? in some of the information fields.
Solution: Change the read modes for the attributes to ReadInstance and
ReadWriteInstance.
2. The CtRemoteApp name is not visible when the Application view is in List
mode.
Solution: Place the mouse pointer over the branch where the name should
be located to view the pop-up description. Use the right mouse button to
view and select the applications subview menu.
SM-CSI1085
Zeitnet ZX-250
1. There are no menu selections for Device view and Configuration view
when right-clicking on the Device icon.
2. A Duplicate IP alarm notification does not occur when a second ZX-250 is
modeled with an IP address used by another ZX-250.
SM-CSI1095
STS16 Token Ring Switch
1. Choosing Device Interface view from the drop down menu, then double
clicking on Interface Description will bring up a default Gib.
2. When in the Device Chassis view, selecting Print from the File menu and
then clicking Print View and OK results in a distortion of the images on
the right side of the view.
3. Port resolution is not completed during autodiscovery.
4. Trap support is not provided in MMS2.
SM-3CM1007
3ComLinkSwitch 1000
In the Security Users view on NT, when an "Add Entry" action fails, a
message box is displayed. Selecting the OK button sometimes causes the
SpectroGRAPH to exit.
SM-3CM1009
FMS Token Ring Device
This device has two cascade ports rather than the one displayed.