User`s guide

WAN Configuration Using Local Management
CSX200 Family User’s Guide 159
4. Use the arrow keys to highlight the SAVE command. Then press ENTER. The message “SAVE
DONE!” displays and Local Management saves the changes to memory.
5. Access the WAN Interface Configuration screen by using the arrow keys to highlight the WAN
Int Config option, then press ENTER.
Frame Relay Interface Configuration
This screen is accessed through the WAN Physical Configuration screen. Refer to Figure 72 and
proceed with the following steps to configure the WAN Interface through Local Management.
1. Use the arrow keys to highlight Interface Number. Set the WAN connection Interface Number
by typing the same number found in the Interfaces field on the WAN Physical Configuration
screen into the Interface Number field, then press ENTER. In this example, the Physical
Configuration screen shown in Figure 71 uses Interface 002 for the WAN connection.
2. Use the arrow keys to highlight Line Coding. Press the SPACEBAR to select None, then press
ENTER.
3. Use the arrow keys to highlight Active Protocol. Press the SPACEBAR to select FR, then press
ENTER.
4. Use the arrow keys to highlight FR LMP. Press the SPACEBAR to select T1.617-D, then press
ENTER.
5. Use the arrow keys to highlight CKT_DCP Enable. Press the SPACEBAR to select ON, if you
want data compression enabled or OFF, if you do not, then press ENTER.
6. Use the arrow keys to highlight the SAVE command. Press ENTER. The message “SAVE
DONE!” displays and Local Management saves the changes to memory. The interface is
assigned to an application port (PT#) in the table.
The WAN configuration is complete. Communications between the CSX200 and the service
provider’s switch takes approximately 1 to 2 minutes to begin. A status of Inactive displays until
both ends of the PVC (Permanent Virtual Circuit) are configured. Once both end devices have
negotiated link management with the switches, the status field reads Active.
NOTE
Set Force CTS and Force DSR to YES only if the CSU/DSU does not support these
flow control terms.