User`s guide

SFVRA Configuration Manager 81
C
ONFIGURING
C
IRCUITS
Configuring Circuit Data Links
Notes: These numbers will populate the telephone numbers for the connection groups. You
may need to modify these telephone numbers under the connection group telephone
information if prefixes are needed. For example, if the dial out call is a long distance
call, you will need to add a 1 and the area code, or, if the system has a Centrex system
you will need to add a 9 before the number.
Also note that once you configure the connection group, all new phone numbers or
modifications to old phone numbers must be done through the connection group;
changes made to the circuit information will not be reflected under the previously
configured connection group information.
CONFIGURING CIRCUIT DATA LINKS
Only for BRI and PRI circuits. All of the shown configured values were automatically incorporated
from the site template associated with the system.
If the circuit’s configuration varies from the values taken from the site template, you can edit these
values.
TEI Negotiation and TEI Value fields may be included for both BRI and PRI circuits. When
configuring data links for BRI circuits, extra fields are included.
Additional BRI circuit information:
Enable/Disable Data Links
Only for BRI circuits. Data links may be disabled completely for all BRI switch types except
DMS100 and NI-1. This is often done when dedicated lines are in use.