MMS3 Known Anomalies
MMS3 Software Characteristics Software Release Notice for 5.0rev1
4-14 CS3 and MMS3
MMS3 Known Anomalies
Following are the known anomalies in MMS3, listed as they apply
(i.e., by device type, management module number, application, or
model type).
SM-CSI1014, Standard RMON App
1. The performance information is red boxed in the Token Ring
Promiscuous Segment Performance view.
2. The RMON Suite SPMA will remain blank indefinitely under
certain conditions of OID comparison for particular model types.
This will be addressed in a future release of SPECTRUM.
SM-CSI1022, MicroMMAC-E
AutoDiscovery hangs indefinitely when reading the Source Address
Table for the model StckRptrRev4 of a BRtrCSIuMMAC with a
firmware revision of 1.32.03. This will be addressed in a future release
of SPECTRUM.
SM-CSI1030, SmartSwitch 9000 (9E132_15)
When a SmartSwitch 9000 is modeled using a Gen9000 Model Type,
the serial number for the device is not displayed in the Banner of the
Configuration, Performance, and Model Information views.
SM-CSI1035, SmartSwitch 9000 FDDI INB Switch
The 9F426-02 and 9F426-03 modules only support RMON events and
alarms and actions. This will be addressed in a future release of
SPECTRUM.
SM-CSI1077, HSIM_SSA_7xx, SSA_7xx
Trap support is not currently working for these models. This will be
fixed in a future release of SPECTRUM.
SM-CSI1085, Cabletron ATM - Zeitnet
1. The ZX-250 Switch Application Port Table view may report the
wrong number of ports. The Num of Ports field may not
correspond to the number of ports listed in the table. This is a
firmware related problem that is fixed with firmware 2.03.28 or
greater.