Specifications

Patches Issued Since the CS2/MMS2 Release
Software Superseded by CS3/MMS3 Software Release Notice for 5.0rev1
5-76 CS3 and MMS3
The problem was that the RMONFilter and RMONPacketCapt had an
OID set by sys_oid_verify when the did not need one. Further, the
OID was identical to the one set for a HubSynTR3xxx model. This was
causing problems when modeling a HubSynTR3xxx with Model by IP.
Upon modeling a HubSynTR3xxx with model by IP the device would
get a yellow alarm and model mismatch error.
The resolution was to remove the sys_oid_verify value for the
RMONFilter and RMONPktCapt model types. Since these models are
applications the value was not needed.
--
The problem was Frame-Relay DTE models were not being created for
the CSX400 model type. There is a model type rfc1313App, which is
specific to the CSX400 model type, but the Frame Relay manager uses
fr1315App to create the DTE's.
The resolution was to add Manages Meta-Rule between CSX_Device
and FrmRlyAppDerPt.
--
The problem was that any model type whose default value for
System_Desc_Verify equaled GENERIC_SNMP_DEVICE would cause
that device (i.e. HubCat5509) to be created instead of a Generic SNMP
Device model type.
The resolution was to change the value of System_Desc_Verify to be
<blank> instead of "GENERIC_SNMP_DEVICE" so that if a customer
models a device for which they do not have a Management Module it
will be correctly modeled as a Generic SNMP Device.
--
The problem was when RMON Probes were used as monitor point for
LAN 802.3 and LAN 802.5 they would not show the same figures as
the RMON Segment View or as other RMON Software (i.e. HP
NetMetrix).
The resolution was to correct the following formulas:
a. WatchUtil - which provides the TR_Mon_Util attribute to the
LAN802.5 GIB view. The formula was changed from:
TR_Mon_Util=TR_Mon_Bytes_Per_Second/TR_Mon_Ring_Speed