Patches Issued Since the CS2/MMS2 Release
Software Superseded by CS3/MMS3 Software Release Notice for 5.0rev1
5-70 CS3 and MMS3
respond to the Get_Address_List action. The GmIHRptrSrcAddr
inference handler is getting "no such attr" errors when attempting to
read attributes that do not exist in the CsRipEnetRptr.
The resolution was to add a new method which can be called by an MI
Node if desired to change which attribute ids are used for reads.
--
The problem was that sometimes the CsIGModel icon in the
QuickFind view (custom view) appeared unselected and could not be
selected manually.
The resolution was to fix the timing issue that was causing this
problem. The CsIGModel should now appear selected and selectable.
--
The problem was when using the NetWideApp to do tftp downloads for
multiple 6H202-24 and 2H252-25R devices it displays an error that
only states "files systems". If the customer tries doing multiple
downloads for other devices it works fine. If the customer tries doing a
download for one device at a time for the 6H202-24 and 2H252-25R
devices it works fine.
The resolution was to add a new -force-ct-download flag. The Netwide
app will now launch mftfp with this flag by default. The syntax is:
mtftp -force-ct-download
NOTE: This function will not work for any of the 9AXXX_XX devices.
--
The problem is that when modeling a Cat1900 the device comes up as
a Rtr_Cisco.
The resolution was to add functionality to recognize a SwCat1900 and
wsc1900LiteFx based on their sysOid values.
The problem is that the SG-Support/CsGib/HubCat5000/CsConfg.GTb
table has incorrect column heights which causes the listbox to create a
horizontal scroll bar outside the viewing area. This causes the
SpectroGRAPH to core dump when viewed if the text exceeds the
specified length.
The resolution was to change the column heights to fit inside the
viewable area.