User`s guide

USER’S GUIDE
136 SFVRA Connection Manager
Other messages that you may encounter are SQL errors and are numbered by the SQL
manufacturer. These numbers have the prefix RDO (Remote Data Object). Refer to the SQL Error
Messages section of the Client System Messages chapter for more detail.
ERROR MESSAGES
Error messages signal that a procedure failed. These messages are indicated by on the dialog
box and contain a description of each error message and suggestions for a resolution.
Convert: 1000 A Login ID must be entered.
The login operation failed because no Login ID was provided. Check with your system
administrator to get the proper Login ID.
Convert: 1001 This version of the SFVRA CONVERT requires SFVRA database version: <version> or later.
The current SFVRA database version is: <current_version>. Cannot get the system information for the
About form.
The Convert application requires the SFVRA database version to be the same or later. This error
occurs when Convert has been upgraded and the database has not. If the Client interface has a later
version than the database, Convert will connect to the database, but you will be unable to view or
change any information. We recommend that you upgrade the SFVRA database before upgrading
the Convert application to avoid this error.
Convert: 1002 System Information is unavailable at this time.
The User Data Source is not defined as a valid user of a trusted SQL server connection, or the
connection to the SQL Server has been dropped since the last action. Ensure under the Control
Panel, 32-bit ODBC, that the User Data Source for “SFVRA” does not have the “Use Trusted
Connection” box checked, or that the server allows this user with a Trusted Connection.
Convert: 1003 This program is available to members of the SFVRARW group only.
Client users that have read only access are unable to run the Convert application. Ensure that your
access rights are accurate with the system administrator.
Convert: 1004 The NETWORK.NEI File or DEVDB.NEI File cannot be opened. Check to see you have
specified the correct path.
Convert was unable to locate the NETWORK.NEI file or DEVDB.NEI file, depending on the version
of UAA software on the CyberSWITCH. Ensure that the specified path and file name is correct.
Convert: 1005 The IP.NEI File cannot be opened. Check to see you have specified the correct path and file
name.
Convert was unable to locate the IP.NEI file. Ensure that the specified path is correct.
Convert: 1006 The Data File cannot be opened. Check to see you have specified the correct path and file name.
Convert was unable to locate the Data File. Ensure that the specified path and file name are correct.
Convert: 1007 Unknown Token encountered. Failure occurred at User Name: <User Name> Token:
<Token>. User Record(s) Processed: <x>. User Record(s) added to the database: <y>.
The Convert application encountered an unknown token in one of the .NEI files. The unknown
token specified in the error statement was found in conjunction with the specified user. Ensure that
this file is not corrupt and the token names are accurate. This message also indicates the number of