Specifications

Chassis Group Views Chassis Views
SPECTRUM Enterprise Manager 50 of 72 Bay Networks Accelar
Num Ports
The total number of ports currently installed in
the chassis.
Test Result
The chassis start-up diagnostic tests. Possible
values are other, ok, crceeprom, timer, procdram,
led, formaccpuaccess, asiccpuaccess, memory,
and loopback.
Isolate Unconfig Ports
Displays whether unconfigured ports should be
assigned to the isolated VLAN. Ports assigned to
this VLAN can only communicate with the CP
port. By default this assigns ports to the default
VLAN.
Use Factory Settings
Displays whether the system will ignore
configuration information stored in NVRAM when
the system is booted.
TFTP Downloads
This area contains information on how to handle
TFTP downloads.
Host
The name of the source/destination host for the
TFTP transfer.
Action
The action to take on download.
File
The name of the file to transfer.
Result
The result of the latest download.
Power Supply Chassis Table
This table contains information about power
supplies.
Id
The id number of the power supply, either 1 or 2.
Operational Status
The actual status of the power supply. Possible
values are:
Fan Chassis Table
This table contains information about fan status.
Table 11: Power Supply Operation Status
Value Description
unknown The status can not be determined.
empty No unit installed.
up Present and active.
down Present but inactive.