9032231 E1 Event and Alarm Messages
4-5
CyberSWITCH 200 Series and 400 Events and Alarms
CsEvFormat/Event000d010b
{d “%w- %d %m-, %Y - %T”} -
Redundancy diagnostics of {m} ({t}),
indicate that the redundant link for
module {I 1}, port {I 3} has failed.
(event [{e}])
CsPCause/Prob000d010b
The cable segment connected to the port
has a cable fault. This should be checked
for continuity as soon as possible in case
the other ports in this redundant circuit
fail and this port is needed.
CsEvFormat/Event000d010f
{d “%w- %d %m-, %Y - %T”} - User
defined traffic threshold - {I 1} packets
within {I 3} seconds, exceeded on
module {I 5} of {m} ({t}). (event [{e}])
CsPCause/Prob000d010f
The packet rate on this module has
exceeded user defined limits. The device(s)
attached to this module may have an
application which requires a large amount
of network bandwidth. If the application
requires a large amount of bandwidth, a
bridge or router could be used to logically
separate various network segments. Use
port level thresholds to further
troubleshoot to a device level.
CsEvFormat/Event000d0110
{d “%w- %d %m-, %Y - %T”} - Error
threshold exceeded. An error
threshold, of {I 1}% of total packets in
{I 5} seconds, exceeded on module in
slot {I 7}. (event [{e}])
CsPCause/Prob000d0110
This threshold will indicate that a
malfunctioning device is present on this
module or that a cable fault exists. A port
level threshold should be set to further
troubleshoot to the offending node.
CsEvFormat/Event000d0111
{d “%w- %d %m-, %Y - %T”} - Collision
threshold exceeded. The number of
collisions per total packets within the
time base of {I 3} seconds has been
exceeded on the module in slot {I 5} of
{m} ({t}). (event [{e}])
CsPCause/Prob000d0111
Collisions are caused by many nodes
contending for the network or cabling
faults. Use port level thresholds to further
troubleshoot to a device level.
CsEvFormat/Event000d0112
{d “%w- %d %m-, %Y - %T”} - Traffic
threshold, {I 1} packets per {I 3}
seconds, exceeded on port {I 7} on
module in slot {I 5} of {m} ({t}). (event
[{e}])
CsPCause/Prob000d0112
The device(s) attached to this port may
have an application which requires a large
amount of network bandwidth. If the
application requires a large amount of
bandwidth, a bridge or router could be
used to logically separate various network
segments.
Table 4-1. CyberSWITCH 200 Series and 400 Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause
Message