Specifications
CyberSWITCH 200 Series and 400 Events and Alarms
Event and Alarm Messages CyberSWITCH Devices (200 Series and 400)
4-4 Management Module Guide
CsEvFormat/Event000d0104
{d “%w- %d %m-, %Y - %T”} - Network
configuration change reported by {m}
({t}). Device previously linked to port
{I 3} on module in slot {I 1} has ceased
to transmit link integrity pulse. (event
[{e}])
CsPCause/Prob000d0104
A device previously linked with this port
has been removed, powered down, or the
cable segment has a fault.
CsEvFormat/Event000d0105
{d “%w- %d %m-, %Y - %T”} - New
source address {X 5}, is detected on
{m} ({t}), port {I 3} of module in slot {I
1}. (event [{e}])
CsPCause/Prob000d0105
A device, previously linked or not, has
transmitted a packet that was received on
this port. The device is either new or has
been powered up but not transmitted a
packet with the aging time period.
CsEvFormat/Event000d0106
{d “%w- %d %m-, %Y - %T”} - Source
address {X 5}, has timed out on port {I
3} of the module in slot {I 1} of {m}
({t}). (event [{e}])
CsPCause/Prob000d0106
A device linked or not linked to this port
has not transmitted a packet during the
aging time period, and has been removed
from the source address table of the
device.
CsEvFormat/Event000d0107
{d “%w- %d %m-, %Y - %T”} - Device
configuration change reported by {m}
({t}). The module in slot {I 1} has been
removed. (event [{e}])
CsPCause/Prob000d0107
A module within this hub has been
removed or has failed.
CsEvFormat/Event000d0108
{d “%w- %d %m-, %Y - %T”} - Device
configuration change reported by {m}
({t}), An (EPIM) has been inserted into
slot {I 1} of the MMAC. (event [{e}])
CsPCause/Prob000d0108
A module has been inserted into this hub.
CsEvFormat/Event000d010a
{d “%w- %d %m-, %Y - %T”} - Network
configuration change reported by {m}
({t}). Port {I 3} in slot {I 1} has now
become active as the result of a
redundancy poll failure. (event [{e}])
CsPCause/Prob000d010a
The polled device has been communicated
with via a backup port and the port is now
active. The other ports in this redundant
circuit are now designated as backup and
are turned off to prevent data loops on the
network.
Table 4-1. CyberSWITCH 200 Series and 400 Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause
Message