Specifications
What Is in This Chapter
Configuration Views SynOptics 28000 Series Switches
3-8 Management Module Guide
Feature Mode
Displays the type of switch. Table 3-8 lists and describes the possible modes.
Topology Mode
Identifies the method used for detection of redundant links to switches.
Possible values are “other” (other or not known), “lattisspan” (SynOptics way),
and “a8021d” (8021: IDMode).
This button opens the Board Information view, which provides the following
information for each board inserted in the chassis. Initially, this table will
describe the single board used by the switch for all functionality including
SNMP management.
Board
Displays the board number.
Status Display
Indicates the current ASCII character display of the board, for boards with
display hardware. Values are concatenated for boards with multiple displays.
Date Code
Displays the date of manufacture of the board, if available, in format:
YYYYmmdd.
Config Source
Indicates the source of the configuration at the last board reset. Table 3-9 lists
and describes the possible sources.
Table 3-8. Feature Modes
Type Description
other other or not known
original Legacy 28115 or 28104 type of original
standard standard 28115
advanced advanced switches (28115/A20 or 28104/A20)
upgradeadvanced upgrade advanced 28115/Advan
Board Information
Table 3-9. Configuration Sources
Source Description
other unknown or some other value
nms from the network management station