Specifications

Application View SmartSwitch Applications
Device Management Page 50 CyberSWITCH and SmartSwitch Access
DisplayStatus
FreezeDisplayStatus
ErrDisplayStatus
CriticalDisplayStatus
StatusDisplayStatus
InfoDisplayStatus
DebugDisplayStatus
Double-clicking on any of the above entries opens
the Client Configuration view, which allows you to
enable or disable these entries. In addition to the
information above, the Client Configuration Table
contains a Server Log Configuration section which
contains the following information:
Auto Freeze
When enabled, logging a FREEZE level message
will prevent any additional messages from being
logged.
Admin Status
The status of the message logging system and the
log itself. If disabled, clients cannot append
messages to the log.
Last Change
The value of “sysUpTime” at the last change to
Auto Freeze or Admin Status.
Log Information View
Access: From the Icon Subviews menu for the
SSA_AapsLogApp Application icon, select Log
Information.
This view contains Log Table information,
including a Recovered Log Table section that
displays log messages recovered due to system
shutdown or power failure. This view also gives
you the ability to move up or down in the log
window and reset the log window to the beginning
of the log table. In addition, you can filter out log
entries by entering a desired “match” string in
either the Event or Client fields and only those
entries that contain the desired string will be
displayed in the Log Table.
SSA_BufferApp
This is the Buffer application, the Icon Subviews
menu associated with this application provides
access to the views described in Table 27.
Table 27: SSA_BufferApp Icon Subviews
Menu
Option Opens the...
Buffer Pool
Information
Buffer Pool Information Table