® MicroMMAC-E Management Module Guide
Notice Cabletron Systems reserves the right to make changes in speciÞcations and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, Þrmware, or software described in this manual is subject to change without notice.
Restricted Rights Notice (Applicable to licenses to the United States Government only.) 1. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. Cabletron Systems, Inc., 35 Industrial Way, Rochester, New Hampshire 03866-5005. 2. (a) This computer software is submitted with restricted rights.
Contents Preface What Is in This Guide .......................................................................................................... ix Conventions .......................................................................................................................... ix Related SPECTRUM Documentation....................................................................................x Other Related Documentation .................................................................................
Chapter 3 ConÞgurationViews What Is in This Chapter .....................................................................................................3-1 Accessing the MicroMMAC-E Device ConÞguration View .........................................3-2 MicroMMAC-E Device ConÞguration View.................................................................3-3 Interface ConÞguration Table ......................................................................................
Figures Chapter 2 Figure 2-1. Figure 2-2. Figure 2-3. Figure 2-4. Figure 2-5. Figure 2-6. Figure 2-7. Device Views MicroMMAC-E Device View ................................................................................. 2-2 Logical Module Fields and Menu Selections ....................................................... 2-3 Port Icon - Device Chassis View ........................................................................... 2-7 Redundantly Connected Devices ..........................................
vi MicroMMAC-E Management Module Guide
Tables Chapter 1 Table 1-1. Chapter 2 Table 2-1. Table 2-2. Table 2-3. Table 2-4. Table 2-5. Table 2-6. Table 2-7. Table 2-8. Table 2-9. Chapter 3 Table 3-1. Chapter 4 Table 4-1. Introduction Stack Repeater....................................................................................................... 1-4 Device Views Module Menu Selections ....................................................................................... 2-5 Stack Menu Selections ...........................................
viii MicroMMAC-E Management Module Guide
Preface You should read this manual if you are going to manage a MicroMMAC-E Device through SPECTRUM. Before reading this manual, you should be familiar with SPECTRUMÕs operation. Familiarity with network management is helpful, as is an understanding of the device hardware and Þrmware described in the MicroMMAC-22E and MicroMMAC-24E 10 Base-T Intelligent Stackable Hub UserÕs Guide.
Related SPECTRUM Documentation Conventions In this manual the following conventions are used: ¥ Command names are printed in bold; for example, Clear or Save & Close. ¥ Menu selections to access a view are printed in bold; for example, ConÞguration or Detail.
Getting Help Getting Help For additional support for SPECTRUM products, or to make comments or suggestions regarding SPECTRUM or this manual, contact Cabletron Systems Technical Support via one of the following means: Location Mail FAX Telephone 603-337-3075 603-337-3500 (*)-44-635-552062 (*)-44-635-580000 Europe Cabletron Systems, Ltd. Network House Newbury Business Park London Road, Newbury Berkshire, England RG13 2PZ E-mail: eurospec@ctron.
Getting Help Preface xii MicroMMAC-E Management Module Guide
Chapter 1 Introduction What Is in This Chapter This chapter describes the SPECTRUM Management Module for the MicroMMAC-E. It will also give you the model type names assigned to the MicroMMAC-E in SPECTRUM. (Model type name refers to the template used to specify attributes, actions, and associations for device models in SPECTRUM.
MicroMMAC-E Applications (e.g., Ethernet to: FDDI network backbones, Wide Area, or Ethernet, etc.). Other optional BRIMs are as follows: ¥ BRIM-E: Ethernet module with selectable media connections ¥ BRIM-F6: FDDI Dual Attached Station (DAS) connection ¥ BRIM-WT1: Wide Area NetworK (WAN) When a BRIM is inserted into a MicroMMAC-E chassis, the icon dynamically changes from a hub icon to a bridging icon, demonstrating the additional bridging functionality provided by the BRIM.
MicroMMAC-E Applications ¥ CtWANAppRS232 - RFC1317sync ¥ DownLoad (CtDownLoadApp) ¥ Repeating (StckRptrRev4) ¥ MIB--II (SNMP2_Agent) - ICMP (ICMP_App) - IP (IP2_App) - System (System2_App) - UDP (UDP2_App) ¥ RMON App - RMONEthProbe ¥ CtWANApp RMON/CtRouter/DLM are also supported. SPECTRUM management of these MIBs are purchased separately.
SPMA and the MicroMMAC-E Table 1-1. Stack Repeater Menu Selection Description Performance Opens the Performance View. See SPECTRUM Performance View Reference. Stack ConÞguration Opens the Stack Repeater Rev 4 (MicroMMac-EÕs Repeater). See Chapter 3 in this guide. Repeater Redundancy Opens the Repeater ConÞguration View. See Chapter 3 in this guide. Repeater Source Address Opens the Source Address View. See SPECTRUM Portable Management Application for the MicroMMAC-E UserÕs Guide.
SPMA and the MicroMMAC-E ¥ Chapter 7, Security, describes how to conÞgure and manage the LANVIEWSECURE feature incorporated into the new generation of CabletronÕs family of stackable hubs. ¥ Chapter 8, Using the MicroMMAC-(E) Bridge View, provides detailed instructions for conÞguring and managing the MicroMMAC-(E)Õs powerful bridging capabilities, including monitoring bridge operation, using the special and Þltering data bases, and setting forwarding thresholds and notiÞcation options.
SPMA and the MicroMMAC-E Introduction 1-6 MicroMMAC-E Management Module Guide
Chapter 2 Device Views What Is in This Chapter This chapter provides a description of the Device View for the MicroMMAC-E Management Module, including an explanation of how to use the Interface, Chassis, and Physical representations of the MicroMMAC-E, access SPECTRUM generic views, and monitor performance. ¥ The Chassis View displays a logical view of the MicroMMAC-E chassis, its interfaces, and the other stacked chassis.
What Is in This Chapter Figure 2-1.
Chassis Device View Chassis Device View The MicroMMAC-E Chassis Device View shows a logical representation of each module in the stack. From this view, you can go into several Þelds that access information about the chassis, the module, the repeater stack, bridging, and the ports. An overview of the process for accessing the Chassis Device View follows. Each representation of a port includes a gauge which shows changes in trafÞc over that port as it occurs.
Chassis Device View Accessing the MicroMMAC-E Chassis Device View Accessing the MicroMMAC-E Chassis Device View Access the Chassis Device View using one of the following methods: ¥ Double-click on the Device View button of the MicroMMAC-E device icon. This will open the Device View that was opened last (i.e. Chassis, Interface, or Physical). Model Name Model Type Device View Button ¥ Highlight the MicroMMAC-E device icon and select Device -> Chassis from the Icon Subviews menu.
Chassis Device View Accessing the MicroMMAC-E Chassis Device View Table 2-1. Module Menu Selections Menu Selection Description uMMAC Model Information (MicroMMAC-E only) Opens the MicroMMAC-E Model Information View. See the SPECTRUM Views reference. uMMAC ConÞguration (MicroMMAC-E only) Opens the MicroMMAC-E ConÞguration View. See the SPECTRUM Views reference. Application View (MicroMMAC-E only) Opens the Application View. See the SPECTRUM Views reference. Module Notes Opens the Module Notes View.
Chassis Device View Ports Table 2-2. Stack Menu Selections (Continued) Menu Selection Description Stack Frame Size & Protocols Opens the Stack Frame Size View. See the SPECTRUM Views reference. Stack ConÞguration Opens the Stack ConÞguration View. See Chapter 3, ConÞguration Views. Stack Model Information Opens the Stack Model Information View. See the SPECTRUM Views reference. Repeater Redundancy Opens the Repeater Redundancy View.
Chassis Device View Ports Figure 2-3. Port Icon - Device Chassis View Port Number - The number uniquely identifying the port. Port Status - The portÕs status. Possible values are: ON, OFF, NLK (no link), or SEG (segmented) 10 NLK Port Statistics - The rate of frames per second received by this port. Pkts 0 Table 2-3 outlines the menu selections and information you can access from the port menu: Table 2-3.
Chassis Device View Redundancy Redundancy SPECTRUM allows redundant circuit connections between any two or more hub devices that have redundant capability in their Þrmware. A circuit is established by a cable connection from one port on a primary hub device to one or more ports on secondary hub devices. The cable connections can use any valid cable type, including UTP/STP, coaxial, or Þber optic. Any two or more cable connections create a complete circular circuit pathway between the two devices.
Interface Device View the MicroMMAC-E, provides a description of the source address views used to establish a source address table for the MicroMMAC-E. Interface Device View This section describes the functions of the Interface Icons and the Interface Options; information about the Device Icon Panel, which displays the MicroMMAC-E Location View Icon, can be found in the SPECTRUM Views reference. The Interface Device View includes three panels shown in Figure 2-5 Figure 2-5.
Interface Device View Accessing the Interface Device View Accessing the Interface Device View You can access the Interface Device View using one of the following methods: ¥ Double-click on the Device View button of the MicroMMAC-E device icon. This will open the Device View that was opened last (i.e. Chassis, Interface, or Physical). Model Name Model Type Device View Button ¥ Highlight the MicroMMAC-E device icon and select Device -> Interface from the Icon Subviews menu.
Interface Device View MicroMMAC-E Interface Icons Panel MicroMMAC-E Interface Icons Panel This section describes the MicroMMAC-E Interface Icon, the iconÕs doubleclick zones, and associated views. Figure 2-6 is a model of the MicroMMAC-E Interface Icon. Figure 2-6. Micro MMAC Interface Icon Close Navigate Alarms Performance Notes...
Interface Device View ConÞguration from the Icon Subviews menu. Table 2-4 describes the information found in the ConÞguration - CSIIfPort View. Table 2-4. ConÞguration - CSIIfPort View Field NOTE Description Interface Index Indicates the value identifying the interface. Interface Type Indicates the type of interface. Operation Status Indicates the current operating condition of the interface for which the entry exists.
Interface Device View Table 2-5. Interface Types (Continued) Interface Type 9031124 E4 Description iso88023 ISO CSMA/CD iso88024 ISO token bus iso88025 ISO token ring iso88026 ISO man starLan StarLAN IEEE (Institute of Electronic & Electrical Engineers) 802.3 Prot10MB ProNET 10 Mbps Prot80MB ProNET 80 Mbps HypChan Hyperchannel FDDI Fiber Distributed Data Interface LAPB X.
Interface Device View Interface Model Information View/MAC Address Label This label gives you the physical address of the MicroMMAC-E interface as well as access to interface model information. Double-clicking on this label of the icon opens the CSI Interface Port Model Information View. (You can also access these views by highlighting the interface icon and using the right mouse button to select Model Information from the Icon Subviews menu.
Interface Device View Interface Options Panel Table 2-6. Color and Statistical DeÞnitions for Each Attribute (Continued) Statistic Color Description % Host Bound yellow The percentage of the total number of packets that have been delivered to the local host from the interface during uptime. # In Packet Rate p/s light blue The total number of packets that have been received by this interface during uptime.
Interface Device View Interface Options Panel Gauge Control Panel View The Gauge Control Panel View allows you to change the type of statistical information presented in the Logical Gauge area of the Logical Interface Icon. To access the Gauge Control Panel, either double-click on the Interface Options Panel or single-click on the panel to highlight it and then use the right mouse button to select Gauge Control Panel from the Icon Subviews menu.
Interface Device View Gauge Type Table 2-7. Gauge Mode Totals Attributes and Color DeÞnitions (Continued) Selected Attribute Table 2-8. Color Transmitted White Filtered Gray Gauge Mode Rate Attributes and Color DeÞnitions Selected Attribute Color Load Green Load In Green Load Out Green Packet Rate Lt. Blue In Packet Rate Lt. Blue Out Packet Rate Lt. Blue % Discard Tan % Filtered Gray % Forwarded Lt.
Interface Device View Gauge Control Panel Buttons Gauge Control Panel Buttons You can control the way the Gauge Control Panel selections affect the logical interface icon through using the following buttons: Keep Settings Click on this button to save the current gauge settings while running SpectroGRAPH. Reset When clicked on, this button resets the settings selections to the last kept settings. Close Click on this button to close the Gauge Control Panel.
The Physical Device View The Physical Device View This section describes the module information available from the MicroMMAC-E Physical Device View, which displays a physical representation of the MicroMMAC-E module and its stack. Accessing the Physical Device View Access the Physical Device View using one of the following methods: ¥ Double-click on the Device View button of the MicroMMAC-E device icon. This will open the Device View that was opened last (i.e. Chassis, Interface, or Physical).
The Physical Device View Accessing the Physical Device View Figure 2-7.
The Physical Device View Accessing the Physical Device View Non-generic selections related to the module icons in the MicroMMAC-E Physical Device View are described in Table 2-9. Table 2-9. Physical Device View - Module Icon Menu Selections Menu Selection 9031124 E4 Description uMMAC Model Information Opens the MicroMMAC-E Model Information View. See the SPECTRUM Views reference. uMMAC ConÞguration Opens the MicroMMAC-E ConÞguration View. See the SPECTRUM Views reference.
The Physical Device View Accessing the Physical Device View Device Views 2-22 MicroMMAC-E Management Module Guide
Chapter 3 ConÞgurationViews What Is in This Chapter This chapter provides general descriptions of the conÞguration views that are available for the MicroMMAC-E. These views allow you to access devicespeciÞc conÞguration information.
What Is in This Chapter Accessing the MicroMMAC-E Device ConÞguration View Accessing the MicroMMAC-E Device ConÞguration View Access the Device ConÞguration View using one of the following methods: ¥ Double-click on the ConÞguration view label of the MicroMMAC-E device icon. Model Name Model Type ConÞguration View Button ¥ Highlight the MicroMMAC-E device icon and select ConÞguration from the Icon Subviews menu.
What Is in This Chapter MicroMMAC-E Device ConÞguration View MicroMMAC-E Device ConÞguration View The MicroMMAC-E Device ConÞguration View provides information on the conÞguration and operating status of the MicroMMAC-E and includes the following information: Contact Status This Þeld indicates if a connection with the device has been established. Firmware Revision The Þrmware revision for the device being modeled. Hardware Revision The hardware revision for the device being modeled.
What Is in This Chapter Interface ConÞguration Table Index Displays the number of the interface. Type The Port Type Label displays the type of MicroMMAC-E interface. Possible interface types are shown in Table 3-1. Table 3-1. Port Interface Types Interface Type ConÞgurationViews 3-4 Description Other None of the following Reg1822 Regular 1822 HDH1822 HDLC Distant Host protocol DDNX25 Defense Data Network X.25 rfc877X25 RFC877 X.
What Is in This Chapter Module and Port ConÞguration Views Table 3-1. Port Interface Types (Continued) Interface Type Description XNSoverIP Xerox Network Service Protocol over IP SLIP Generic Serial Line IP ULTRA ULTRA Technologies T-3 T3 link SMDS Switched Multimegabit Data Service FrameRelay T1 Frame relay Phy Address The Ethernet (MAC) address of the interface. Max Frame Size The maximum frame size for the MicroMMAC-E interfaces.
What Is in This Chapter Port Management (Port ConÞguration View Only) Ports Operational The number of operational ports on this module. Module Ports Setting this Þeld to Enable enables all the ports on this module. Disable will disable all ports on the module. You can also enable module ports by selecting Enable All Module Ports from the Icon Subviews menu for the module.
What Is in This Chapter Alarm ConÞguration Link Traps When enabled, all packets indicating a change in link status are reported within the trap database. Segmentation Traps When enabled, all packets indicating a change in segmentation status are reported within the trap database. Source Address Traps When enabled, all packets indicating a change in source address are reported within the trap database.
What Is in This Chapter Error Source preventing excessive network trafÞc from alarm messages transmitted by the module and aids in module troubleshooting. Broadcast Alarms This Þeld displays whether broadcast alarms are disabled or enabled. You can update this Þeld. Broadcast Threshold The threshold value within the alarm timebase which, once that number of broadcast packets is exceeded, generates a broadcast alarm. You can update this Þeld.
Stack Repeater ConÞguration View Runts The number of runt packets received by the module. A runt packet is one byte less than the standard Ethernet frame of 64 bytes (not including preamble). OOW_Colls The number of collisions out of the standard window (51.2µs) due to a network problem. Alignment The number of misaligned packets detected by the module. No_Resource The number of times the module ran out of resources (i.e., lack of buffer space) and could not accept packets.
Stack Repeater ConÞguration View Source Address Management Network Ports Allows you to Enable/Disable the network ports on this network segment. You can update this Þeld. Network Port Security Allows you to Lock/Unlock repeater ports. You can update this Þeld. Source Address Management This section of the Repeater ConÞguration View indicates the timeout period in seconds. Aging Interval The time, in seconds, that dynamically learned forwarding information remains in the database before being selected.
Stack Repeater ConÞguration View Error Source Timebase This Þeld allows you to set the alarm timebase. The timebase is the number of seconds used as the interval for performing all of the rate alarm checks. The minimum is 10 seconds. For example, if the timebase is 10 seconds, an alarm will occur only when the speciÞed number of errors occurs within 10 seconds. TrafÞc Alarms This Þeld displays whether trafÞc alarms are disabled or enabled. You can Enable/Disable trafÞc alarms.
Stack Repeater ConÞguration View Board Map CRC The amount of packets received by the module with bad CRC. Runts The amount of runt packets received by the module. A runt packet is one byte less than the standard Ethernet frame of 64 bytes (not including preamble). OOW_Colls The amount of collisions out of the standard window (51.2µs) due to a network problem. Alignment The amount of misaligned packets detected by the module. No_Resource The number of times the module ran out of resources (i.e.
Chapter 4 Event and Alarm Messages What Is in This Chapter This chapter describes the types of events and alarms generated by the MicroMMAC-E and provides any probable cause messages corresponding to these alarms. MicroMMAC-E Events and Alarms Table 4-1 lists typical events and alarms for the MicroMMAC-E. Table 4-1.
MicroMMAC-E Events and Alarms Table 4-1. MicroMMAC-E Events and Alarms (Continued) Message in the Event Log Alarm View CsEvFormat/Event00010307 {d Ò%w- %d %m-, %Y - %TÓ} - A(n) {t} device, named {m} has been warm started. (event [{e}]) No Probable Cause Message CsEvFormat/Event00010308 CsPCause/Prob00010308 {d Ò%w- %d %m-, %Y - %TÓ} - A(n) {t} device, named {m}, has detected a communication Link Down. (event [{e}]) Communication link is down.
Index Symbols % Discarded 2-14 % Error 2-14 % Host Bound 2-15 % Transmitted 2-14 A ADDRESS 2-15 Admin.
F FDDI 2-13, 3-4 Fiber Distributed Data Interface 2-13, 3-4 Filtered 2-17 Find 2-15 Firmware Revision 3-3 Forwarded 2-16, 2-17 FrameRelay 2-13, 3-5 G Gauge Control Panel 2-16 Mode 2-16 Type 2-17 Generic Serial Line IP 2-13, 3-5 View 2-1 Banner 3-2 Giant Packets 3-9 Giants 3-9, 3-12 Gray 2-17 Green 2-15, 2-16, 2-17 H Hardware Revision 3-3 HDH1822 2-12, 3-4 HDLC Distant Host protocol 2-12, 3-4 Host Bound 2-16, 2-17 HyChan 2-13, 3-4 Hyperchannel 2-13, 3-4 I IBM Synchronous Data Link Control Protocol 2-13, 3
M (Continued) Misaligned Packets 3-9 Module ConÞguration View 3-5 Management 3-5 Type 2-4 Mustard Green 2-15 N NAME 2-15 Network Information 2-15 Panel Label 2-14 Port 3-10 Security 3-10 No Resource 3-9 No_Resource 3-12 Notice i Number of Interfaces 3-3 O OOW Colls 3-12 Oper Status 3-5 Operation Status 2-12 Orange 2-14, 2-16, 2-17 Other 2-12, 3-4 Out Load 2-15 Octets 2-16 Packet 2-16 Rate 2-15, 2-17 P Packet Rate 2-17 Percentages 2-16 Phy Address 3-5 Point to Point Protocol 2-13, 3-4 Polling Cycle 2-1 Po
S (Continued) Segmentation Traps 3-10 Selected Attribute 2-16 Set Topological State 3-6 SFTWARLPBK 2-13, 3-4 SLIP 2-13, 3-5 SMDS 2-13, 3-5 SNMP 1-1 Software Emulation 1-1 Loopback 2-13, 3-4 Source Address Management 3-10 Traps 3-10 SPMA Alarm ConÞguration 1-4 Bridge View 1-5 Community Names 1-5 Generic SNMP (MIB I II) 1-5 Hub View 1-4 Link/Seg Traps 1-4 Repeater Redundancy 1-4 Security 1-5 Source Addressing 1-4 TFTP Download 1-5 Trap Table 1-5 StarLan 2-13, 3-4 StarLAN IEEE 802.