Specifications
Events and Alarms
Event and Alarm Messages ESX Devices
4-4 Management Module Guide
CsEvFormat/Event000d0106
{d "%w- %d %m-, %Y - %T"} Source
address {X 5}, has timed out on port {I 3}
of the module in slot {I 1} of {m} ({t}).
(event [{e}])
CsPCause/Prob000d0106
A device linked or not linked to this port
has not transmitted a packet during the
aging time period, and has been removed
from the source address table of the
device.
CsEvFormat/Event000d0107
{d "%w- %d %m-, %Y - %T"} Device
configuration change reported by {m} ({t}).
The module in slot {I 1} has been removed.
(event [{e}])
CsPCause/Prob000d0107
A module within this hub has been
removed or has failed.
CsEvFormat/Event000d0108
{d "%w- %d %m-, %Y - %T"} Device
configuration change reported by {m} ({t}),
An (EPIM) has been inserted into slot {I 1}
of the MMAC. (event [{e}])
CsPCause/Prob000d0108
A module has been inserted into this hub.
CsEvFormat/Event000d0109
{d "%w- %d %m-, %Y - %T"} Network
configuration change reported by {m} ({t}).
Port {I 3} in slot {I 1} has failed
redundancy polling and has switched to a
backup port. (event [{e}])
CsPCause/Prob000d0109
The polled device(s) in the redundant
circuit polling list have failed to respond.
The device(s) have failed, been powered
down or a cable fault from the active port
to the polled device has occurred. Check
the retry count as it may need to be
adjusted on a busy network segment.
Normal collision occurrences may occur
causing the poll packet to not reach it's
destination.
CsEvFormat/Event000d010a
{d "%w- %d %m-, %Y - %T"} Network
configuration change reported by {m} ({t}).
Port {I 3} in slot {I 1} has now become
active as the result of a redundancy poll
failure. (event [{e}])
CsPCause/Prob000d010a
The polled device has been communicated
with via a backup port and the port is now
active. The other ports in this redundant
circuit are now designated as backup and
are turned off to prevent data loops on the
network.
CsEvFormat/Event000d010b
{d "%w- %d %m-, %Y - %T"} Redundancy
diagnostics of {m} ({t}), indicate that the
redundant link for module {I 1}, port {I 3}
has failed. (event [{e}])
CsPCause/Prob000d010b
The cable segment connected to the port
has a cable fault. This should be checked
for continuity as soon as possible in case
the other ports in this redundant circuit
fail and this port is needed.
Table 4-1. Device Events and Alarms