Specifications
2-62 SmartSwitch ATM Switch Reference Manual
CpuSwitchover Console Commands
CpuSwitchover
(SmartSwitch 6500 Only)
Use CpuSwitchover to manually switch roles of the redundant (slave) and master TSM/CPU modules (the slave
module becomes the master module and vice versa). The
execute cpuswitchover command is available only if a slave
TSM/CPU module is present.
Note CPU switchover occurs automatically if support for automatic TSM/CPU
redundancy has been activated and is operational. You activate automatic
TSM/CPU redundancy with the RedundancyOn attribute.
Operators
execute
Parameters
This attribute has no output parameters.
Descriptions
Examples
switch_prompt # execute cpuswitchover
BackupConfig(N) :
Backup the config and restore it on the redundant CPU when it boots up.
Input Parameter Description Value/Field Size Default
[BackupConfig] Sets/unsets a flag to backup configuration. Y (Yes), N (No) Y
Operator Parameters/Permissions Description
execute
cpuswitchover
[BackupConfig] <backupconfig>
Administrator
Switches the slave TSM/CPU module to the master
TSM/CPU module and vice versa. The current
master configuration is backed up before the
switchover is made. After the switchover, the master
configuration is restored to the new master (the
module that was the slave before the switchover).