Specifications
SmartSwitch ATM Switch Reference Manual 2-235
PortTrafficCongestion
PortTrafficCongestion
Use PortTrafficCongestion to manage traffic congestion at switch ports. You can program the values for the minimum
and maximum threshold (in number of cells) for a specified priority queue. If the number of cells received by the switch
on the specified priority queue for a port exceeds the maximum threshold, the switch discards the cell.
Note You program values for minimum and maximum threshold by entering index
numbers that correspond to cell numbers. Use MinMaxTableIndex to see the
correspondance between index numbers and cell numbers.
Operators
modify, show
Parameters
Parameter Description Value/Field Size Default
[PortNumber] Port number on the switch. A1 to B4 (2500 family),
1A1 to 8B4 (6500),
or All
All
[QueueNumber] Priority queue. 1-5 No default
[MinIndexNumber] Index number for minimum cell threshold
value. Enter
show minmaxtable to view
possible values.
0-15 No default
[MaxIndexNumber] Index number for maximum cell threshold
value. Enter
show minmaxtable to view
possible values.
0-15 No default
Output Parameter Description
[Port ID] Port number on the switch.
[QueueId] Priority queue. (Same as the [QueueNumber] input parameter.)
[ServiceClass] Service category. Possible values are: CBR, RTVBR, NRTVBR, ABR, and UBR.
[MinIndex] Index number for minimum cell threshold value. (Same as the [MinIndexNumber] input
parameter.)