Specifications

SmartSwitch ATM Switch Reference Manual 2-111
LECSNeighbor
LECSNeighbor
Use LECSNeighbor to add or delete LECS synchronization neighbors. The LECS neighbors are on other switches and
communicate with the LECS on this switch (local LECS). The LECS neighbors provide the local LECS with
information about LES servers attached directly to them. In turn, the local LECS provides its LECS neighbors with
information about LES servers attached directly to it. From the perspective of each remote LECS, the local LECS is
an LECS neighbor.
Note An LES is considered directly attached to an LECS if it has established a VCC to
that LECS (to get configuration information from that LECS). The LES is not
necessarily on the same switch as the LECS to which it is directly attached. Each
LES is colocated with a BUS. Though the LES and BUS are separate entities, the
two together are considered an instance of LES/BUS servers. The BUS is not
attached to an LECS, but it exchanges information with the LECS indirectly
through the LES colocated with the BUS.
Operators
add, delete
Parameters
Descriptions
Input Parameter Description Value/Field Size Default
[NeighborATMAddress] ATM address of the LECS neighbor
to add or delete.
No Default
Operator Parameters/Permissions Description
add
lecsneighbor
[NeighborATMAddress]
<neighboratmaddress>
Administrator
Adds an LECS neighbor.
delete
lecsneighbor
[NeighborATMAddress]
<neighboratmaddress>
Deletes an LECS neighbor.