Specifications

LEX CONFIGURATION
WPIM-SY LOCAL MANAGEMENT GUIDE 2-11
2.4 LEX CONFIGURATION
This section provides step-by-step instructions for connecting the
WPIM-SY to a DDS (Digital Data System) circuit in a LEX environment.
The line configuration information shown in Table 2-1, “Telco
Configuration Information,” on page 8 must be supplied by the service
provider.
2.4.1 WPIM-SY Physical Configuration
Begin the WPIM-SY configuration by accessing the WAN Configuration
screen through Local Management (Figure 2-1). Access the WAN
Physical Configuration screen from the Feature Selection screen that first
appears when you enter Local Management. Use the arrow keys to
highlight the WAN Configuration option, then press ENTER. The screen
shown in Figure 2-1 appears. Proceed with the following steps:
1. Use the arrow keys to highlight the [WPIM] field at the bottom of the
screen. Press the SPACEBAR to select the WPIM being configured,
then press ENTER.
2. Use the arrow keys to highlight SYNC PORT TYPE. Press the
SPACEBAR to set the Sync Port Type to V.35, RS422, RS232, or
X.21, then press ENTER.
3. Use the arrow keys to highlight FORCE CTS. Press the SPACEBAR
to set to NO, then press ENTER.
4. Use the arrow keys to highlight FORCE DSR. Press the SPACEBAR
to set to NO, then press ENTER.
Table 2-2. Telco Configuration Information
Configuration Information
Required By User
Configuration Information
Supplied By Service Provider
Clock Source Telco provided or no clock source
Circuit Speed 64K, V.35, RS-422, RS-232, etc.