Specifications

CHAPTER 2: LOCAL MANAGEMENT
2-24 WPIM-E1 LOCAL MANAGEMENT GUIDE
8. Access the WAN Interface Configuration screen by using the arrow
keys to highlight the WAN Int Config option and then press ENTER.
2.6.2 WPIM-E1 Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Refer to Figure 2-4 and proceed with the following steps to configure the
WAN Interface through Local Management.
1. Set the WAN connection Interface Number by typing the same
number into the Interface Number field that was input into the
Timeslots in the WAN Physical Configuration screen, then press
ENTER. (see NOTE on page 2-23).
2. Unless the user sets the Max Xmit Unit, the WPIM-E1 automatically
sets the Max Xmit Unit to 8191 (default) after the active protocol
(PPP) is selected.
3. If the E1 Line Coding is HDB3 on the previous screen:
a. Use the arrow keys to highlight Line Coding. Press the
SPACEBAR to select None, then press ENTER.
b. Use the arrow keys to highlight Active Protocol. Press the
SPACEBAR to select PPP, then press ENTER.
c. Use the arrow keys to highlight PPP Type. Press the SPACEBAR
to select LEX, then press ENTER.
4. If the E1 Line Coding is AMI on the previous screen:
a. Use the arrow keys to highlight Line Coding. Press the
SPACEBAR to select INV-HDLC, then press ENTER.
b. Use the arrow keys to highlight Active Protocol. Press the
SPACEBAR to select PPP, then press ENTER.
c. Use the arrow keys to highlight PPP Type. Press the SPACEBAR
to select LEX, then press ENTER.