Specifications
FRAME RELAY CONFIGURATION
WPIM-E1 LOCAL MANAGEMENT GUIDE 2-19
The line configuration information shown in Table 2-3 must be supplied
by the service provider.
2.5.1 WPIM-E1 Physical Configuration
Begin the WPIM-E1 configuration by accessing the WAN Physical
Configuration screen through Local Management (Figure 2-1). Proceed
with the following steps:
1. Use the arrow keys to highlight the [WPIM] field at the bottom of the
screen. Press the SPACEBAR to select the WPIM being configured,
then press ENTER.
2. Use the arrow keys to highlight Timeslot View. Press the
SPACEBAR to select New, then press ENTER. The cursor moves to
Timeslot #2 of the Timeslot Configuration Table.
3. Insert an interface number (see NOTE below) into every Timeslot
being used. Type the number, press ENTER, then use the arrow keys
to highlight the next Timeslot field. Exit this field by using the arrow
keys. The cursor automatically moves to the E1 Line Coding field.
Table 2-3. Telco Configuration Information
Configuration Information
Required By Customer
Information Supplied By
Service Provider
Line Coding HDB3 or AMI
Frame Type E1 or E1-CRC
Clock Source Loop Timing or Local Timing
DSO’s (Timeslots)
Timeslots being used for each end of
the circuit