Specifications
CHAPTER 2: LOCAL MANAGEMENT
2-20 WPIM-T1 LOCAL MANAGEMENT GUIDE
5. Use the arrow keys to highlight T1 Frame Type. Press the
SPACEBAR to select ESF or D4, then press ENTER.
6. Use the arrow keys to highlight T1 Tx Clock Source. Press the
SPACEBAR to select Local (no clock source provided by telephone
company) or Loop (clock source provided by telephone company),
then press ENTER.
7. Use the arrow keys to highlight T1 Line Buildout (LBO). Press the
SPACEBAR to select to 0 dB unless the service provider recommends
another setting, then press ENTER.
8. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message “Save Done!” appears and Local Management
saves the changes to memory.
9. Access the WAN Interface Configuration screen by using the arrow
keys to highlight the WAN Int Config option, then press ENTER.
2.5.2 WPIM-T1 Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Proceed with the following steps to configure the WAN Interface through
Local Management.
1. Set the Interface Number that is being used for the WAN connection
by typing the same number into the Interface Number field that was
input into the Timeslots in the WAN Physical Configuration screen,
then press ENTER (see NOTE on page 2-19).
2. Use the arrow keys to highlight Line Coding. Press the SPACEBAR
to select None, then press ENTER.
3. Use the arrow keys to highlight Active Protocol. Press the
SPACEBAR to select FR, then press ENTER.
If you are using a Local clock source, set only one end of the
circuit for Local, the other end must be set for Loop.
!
CAUTION