Specifications

CHAPTER 2: LOCAL MANAGEMENT
2-16 WPIM-T1 LOCAL MANAGEMENT GUIDE
5. Use the arrow keys to highlight T1 Frame Type. Use the SPACEBAR
to select ESF or D4, then press ENTER.
6. Use the arrow keys to highlight T1 Tx Clock Source. Use the
SPACEBAR to select Local (no clock source provided by telephone
company) or Loop (clock source provided by telephone company),
then press ENTER.
7. Use the arrow keys to highlight T1 Line Buildout (LBO). Press the
SPACEBAR to select 0 dB unless the service provider recommends
another setting, then press ENTER.
8. Use the arrow keys to highlight T1 Network Loopback. Press the
SPACEBAR to select None, then press ENTER.
9. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message “Save Done!” appears and Local Management
saves the changes to memory.
10. Access the WAN Interface Configuration screen by using the arrow
keys to highlight the WAN Int Config option, then press ENTER.
2.4.2 WPIM-T1 Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Proceed with the following steps to configure the WAN Interface through
Local Management.
1. Set the WAN connection Interface Number by typing the same
number into the Interface Number field that was input into the
Timeslots in the WAN Physical Configuration screen, then press
ENTER (see NOTE on page 2-15).
If you are using a Local clock source, set only one end of the
circuit for Local, the other end must be set for Loop.
!
CAUTION