Technical data

9031240 E5 ConÞguration Views
3-7
SMT Device ConÞguration View
which represents 12.5 bit errors per second (refer to Figure 3-1). This value
can be changed.
Link Error Rate Alarm
The link error rate threshold which, if exceeded generates an alarm for the
port. The default link error rate alarm threshold is 8, which represents 1.25
bit errors per second (refer to Figure 3-1). This value can be changed.
Link Error Monitor Reject Count
The link error monitor count of the times the link has been rejected.
SMT Device ConÞguration View
The SMT Device ConÞguration View provides information on the
conÞguration and operating status of the concentrator. To access this view,
click on the FddiSMT Application Icon in the Application View to highlight it,
and select ConÞguration from the Icon Subviews menu.
Station ConÞguration View
This section of the SMT Device ConÞguration View provides conÞguration
information on the FDDI station. This conÞguration information is as follows:
Ring State
The current state of the FDDI Ring. Table 3-2 provides the possible states.
Table 3-2. FDDI Ring States
Ring States Description
Isolated The concentrator is not attached to the ring.
Non-Op The concentrator is attempting to enter the ring.
Ring-Op The ring is operational.
Detect The claim/beacon process of the FDDI ring protocol has
exceeded 1 second. This indicates a potential problem.
Non-Op-Dup The ring failed to complete the claim/beacon process
because a duplicate FDDI address has been detected.
Ring-Op-Dup The ring is operational but a duplicate FDDI address has
been detected.