Specifications
ATX Switch Events and Alarms
Event and Alarm Messages ATX Switch
4-4 Management Module Guide
CsEvFormat/Event019d0016
{d "%w- %d %m-, %Y - %T"} - Device, {m},
has rebooted, because of a Fatal Error.
The error information string is {0 3}.
Trap severity is {T SMC_Severity 1}.
CsPCause/Prob019d0016
Device rebooted because of a fatal
error.
CsEvFormat/Event019d0017
{d "%w- %d %m-, %Y - %T"} - For device,
{m}, the Configuration EEPROM has
failed. The device can not be rebooted,
and must be returned to the factory. Trap
severity is {T SMC_Severity 1}.
CsPCause/Prob019d0017
The Configuration EEPROM has
failed. The device can not be
rebooted, and must be returned to
the factory.
CsEvFormat/Event019d0018
{d "%w- %d %m-, %Y - %T"} - Device, {m},
has outbound congestion, and discarded
{I 3} packets. Trap severity is {T
SMC_Severity 1}.
CsPCause/Prob019d0018
Packets discarded, because of
outbound congestion.
CsEvFormat/Event019d0021
{d "%w- %d %m-, %Y - %T"} - Device, {m},
reports the number of hardware errors
in received and transmitted packets
exceeds the port’s limit. Discarded {I 3}
received packets. Discarded {I 5}
transmit packets. Trap severity is {T
SMC_Severity 1}.
CsPCause/Prob019d0021
The number of hardware errors in
received and transmitted packets
has exceeded the port’s limit.
CsEvFormat/Event019d0200
{d "%w- %d %m-, %Y - %T"} - A FDDI
port on device, {m} of type {t} has
detected an attachment configuration
change. The new state is
{T FDDISMTCFState3}. Trap severity is
{T SMC_Severity 1}.
CsPCause/Prob019d0200
PROBABLE CAUSE: The FDDI
MAC physical connection has
changed.
RECOMMENDED ACTIONS: 1)
Refer to Event log for current
attachment state. 2) Check the A
and B port connections. 3) Check
the upstream and downstream
devices.
Table 4-1. ATX Switch Events and Alarms (Continued)
Message in the Event Log
Alarm View Probable Cause
Message