Specifications
PATH Group
ATX MIB Reference Guide 5-13
fddimibPATHSMTIndex {fddimibPATHEntry 1}
Integer Read-Only
The value of the SMT index associated with this PATH.
fddimibPATHIndex {fddimibPATHEntry 2}
Integer Read-Only
Index variable for uniquely identifying the primary and secondary PATH object
instances (corresponds to ANSI {fddiPATH 11}). This is 1 (for a primary path) or
2 (for a secondary path).
fddimibPATHTVXLowerBound {fddimibPATHEntry 3}
FddiTime Read-Write
Specifies the minimum time value of fddiMACTvxValue that shall be used by the
MAC that is configured in this path (corresponds to ANSI {fddiPATH 21}). The
operational value of fddiMACTvxValue is managed by setting this variable.
Possible values range from 40960 (40.96 microseconds) to 5202000 (5.2
milliseconds).
fddimibPATHTMaxLowerBound {fddimibPATHEntry 4}
FddiTime Read-Write
Specifies the minimum time value of fddiMACTMax that shall be used by the
MAC that is configured in this path (corresponds to ANSI {fddiPATH 22}). The
operational value of fddiMACTMax is managed by setting this variable. Possible
values range from 40960 (40.96 microseconds) to 167769600 (167,7696
milliseconds).
fddimibPATHMaxTReq {fddimibPATHEntry 5}
FddiTime Read-Write
Specifies the maximum time value of fddiMACTReq that shall be used by the
MAC that is configured in this path. The operational value of fddiMACTReq is
managed by setting this variable. Possible values are the same as
fddimibPATHTmaxLowerBound.