Specifications

Chapter 5: FDDI MIB
5-2 ATX MIB Reference Guide
5.1.1 SMT Table
fddimibSMTTable {fddimibSMT 2}
Not-Accessible
A list of interface entries; one per FDDI port. The entries are indexed by
fddimibSMTIndex.
fddimibSMTEntry {fddimibSMTTable 1}
Not-Accessible
A set of operational attributed for an FDDI port. The individual components are
described below.
fddimibSMTIndex {fddimibSMTEntry 1}
Integer Read-Only
A unique value for each SMT. The values do not correspond to the unit’s port
numbers. For example, parameter instance {fddimibSMTIndex 1} corresponds to
the unit’s first FDDI port, which cannot be port number 1, since port number 1 is
the UART.
fddimibSMTStationID {fddimibSMTEntry 2}
Octet String Read-Write*
Used to uniquely identify an FDDI station (corresponds to ANSI {fddiSMT 11}).
Setting the lower six bytes to zero will cause the unit to automatically use the
port’s MAC address in the lower six bytes.
fddimibSMTOpVersionID {fddimibSMTEntry 3}
Integer Read-Only
The version that this station is using for its operation (corresponds to ANSI
{fddiSMT 13}, refer to ANSI 7.1.2.2). The value of this variable is 2 for this
SMT revision.
fddimibSMTHiVersionID {fddimibSMTEntry 4}
Integer Read-Only
The highest version of SMT that this station supports (corresponds to ANSI