Specifications

Token Ring Group
ATX MIB Reference Guide 4-5
dot5StatsACErrors {dot5StatsEntry 4}
Counter Read-Only
This counter is incremented when a station receives an AMP or SMP frame in
which A is equal to C is equal to 0, and then receives another SMP frame with A
is equal to C is equal to 0 without first receiving an AMP frame. It denotes a
station that cannot set the AC bits properly.
dot5StatsAbortTransErrors {dot5StatsEntry 5}
Counter Read-Only
This counter is incremented when a station transmits an abort delimiter while
transmitting.
dot5StatsInternalErrors {dot5StatsEntry 6}
Counter Read-Only
This counter is incremented when a station recognizes an internal error.
dot5StatsLostFrameErrors {dot5StatsEntry 7}
Counter Read-Only
This counter is incremented when a station is transmitting and its TRR timer
expires. This condition denotes a condition where a transmitting station in strip
mode does not receive the trailer of the frame before the TRR timer goes off.
dot5StatsReceiveCongestions {dot5StatsEntry 8}
Counter Read-Only
This counter is incremented when a station recognizes a frame addressed to its
specific address, but has no available buffer space indicating that the station is
congested.
dot5StatsFrameCopiedErrors {dot5StatsEntry 9}
Counter Read-Only
This counter is incremented when a station recognizes a frame addressed to its
specific address and detects that the FS field A bits are set to 1 indicating a
possible line hit or duplicate address.
dot5StatsTokenErrors {dot5StatsEntry 10}
Counter Read-Only
This counter is incremented when a station acting as the active monitor
recognizes an error condition that needs a token transmitted.