Specifications
Chapter 2: TCP/IP MIB-II
2-2 ATX MIB Reference Guide
HT the name TURBO followed by 24 characters which are all blanks. If
the board is removable, then the 24 characters contain a part number
and serial number. If the board is revocable and has been removed,
then the name is NONE followed by 25 blanks.
Hn the name of each IOM followed by a 24 character manufacturing code
(which contains a part number and serial number). Each IOM name is
padded with blanks, if necessary, so that it is 5 characters. The IOM
names are the following.
CEIOM Ethernet or 802.3 (i.e., 10 megabit CSMA/CD) module with a built-in
concentrator
EIOM Ethernet or 802.3 module
FIOM FDDI module
HIOM HSSI module
IFIOM Intelligent FDDI module
NONE no module (the manufacturing code is all blanks)
TIOM Token Ring (i.e., 802.5) module
QEIOM Quad Ethernet module, i.e., an Ethernet module with 4 ports
QTIOM Quad Token Ring module, i.e., a Token Ring module with 4 ports
sysObjectID {system 2}
Object Identifier Read-Only
The identifier of the variable used to identify the type of entity. Cabletron’s MIB
sysID parameter will have a value that indicates that it is a hub/bridge/router. So
sysObjectID contains the object identifier of the Cabletron MIB sysID object,
i.e.,
{1 3 6 1 4 1 97 1 1}.
sysUpTime {system 3}
TimeTicks Read-Only
The time, in centiseconds, since the unit was last booted.
sysContact {system 4}
DisplayString Read-Write
The name and address of the contact person for the unit. The first 24 characters of
sysContact are copied as the UserData information for FDDI SMT frames.