Specifications

ATX Group
ATX MIB Reference Guide 10-65
rebootIndex {rebootEntry 1}
Integer Read-Only
The slot number, beginning with 1 for the first slot. This number always matches
the instance of the rebootEntry. For example, {rebootIndex 3} contains the value
“3”.
rebootType {rebootEntry 2}
Integer Read-Write
The desired module type of the slot. See hwDefType.
rebootUseMod {rebootEntry 3}
Integer Read-Write
Whether to use this module, not applicable for the Packet Processing Engine.
Possible values 1 or 3. See hwUseMod.
rebootPortType {rebootEntry 4}
Octet string Read-Write
This is a 4 byte array each element represents the types of the ports belonging to
this module (see hwPortType).
rebootConfig {reboot 3}
Integer Read-Write
The configuration file that will be used when the unit reboots. This parameter is
normally automatically set by the unit; however, an NMS may explicitly set it to
either no-change (1) or revert-to-defaults (3). The possible values include:
no-change (1) - the unit will not change its configuration parameters when it
re-boots.
tftp-config (2) - the unit will use a file that was sent via TFTP when it re-boots.
revert-to-defaults (3) - the unit will revert to its factory specified defaults
when it re-boots.
rebootRouteMemory {reboot 4}
Integer Read-Write
Percentage of non-bridging memory to allocate for routing tables. The remainder
will be used for transient packets such as ARP and RIP.