Specifications
Chapter 10: Cabletron MIB
10-54 ATX MIB Reference Guide
sfddiSmtConditionsStatus {sfddiEntry 13}
Integer Read-Write
Requested SMT conditions which are currently present (see
sfddiSmtConditions). Writing to sfddiSmtConditionsStatus is used to
acknowledge the SNMP Traps (refer to chapter 11).
sfddiSrfConditionsStatus {sfddiEntry 14}
Integer Read-Write
Requested SRF conditions which are currently present (see sfddiSrfConditions).
Writing to sfddiSrfConditionsStatus is used to acknowledge the SNMP Traps
(see chapter 11).
sfddiSrfReportLimit {sfddiEntry 15}
Obsolete
sfddiFrameErrorThreshold {sfddiEntry 16}
Obsolete
sfddiNotCopiedThreshold {sfddiEntry 17}
Integer Read-Write
Value for the fddiMACNotCopiedThreshold variable.
sfddiSBFlag {sfddiEntry 18}
Boolean Read-Only
Whether the ECM’s optical bypass is stuck, i.e., the current value of the SMT
SB_Flag variable.
sfddiRxEbits {sfddiEntry 19}
Counter Read-Only
The number of packets that were discarded because another station had already
set the E bit.
sfddiOBSFuseBad {sfddiEntry 20}
Boolean Read-Only
Whether the fuse to the FDDI port’s optical bypass is bad.
sfddiThruB {sfddiEntry 21}
Boolean Read-Write
Whether to connect to the FDDI port B (not applicable for SAS).