Specifications
Chapter 7: Repeater MIB
7-12 ATX MIB Reference Guide
rptrMonitorPortVeryLongEvents {rptrMonitorPortEntry 12}
Counter Read-Only
This counter is incremented by one for each CarrierEvent on this port whose
ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3
(Ref 9.6.1 & 9.6.5, IEEE 802.3 Std). Other counters may be incremented as
appropriate.
rptrMonitorPortDataRateMismatches {rptrMonitorPortEntry 13}
Counter Read-Only
This counter is incremented by one for each frame received on this port that
meets all of the following conditions: a) The CollisionEvent signal is not
asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The
frequency (data rate) is detectably mismatched from the local transmit frequency.
The exact degree of mismatch is vendor specific and is to be defined by the
vendor for conformance testing. When this event occurs, other counters whose
increment conditions were satisfied may or may not also be incremented, at the
implementor’s discretion. Whether or not the repeater was able to maintain data
integrity is beyond the scope of this standard.
This is polled from the RIC event-record-register ELBER (elasticity buffer error)
bit, ten times per second. As such, it is subject to under-counting.
rptrMonitorPortAutoPartitions {rptrMonitorPortEntry 14}
Counter Read-Only
This counter is incremented by one for each time the repeater has automatically
partitioned this port. The conditions that cause port partitioning are specified in
the partition state machine in Section 9 (IEEE 802.3 Std). They are not
differentiated here.
This is polled from the RIC event-record-register PART bit, ten times per second.
As such, it is subject to under-counting.