Installation guide
4-5
SLIP/PPP Problems
If the TCP MSS given by the SLIP host exceeds the MTU on the SLIP line, poor
performance, failed connections, and fragmentation occur. Adjust the MTU on the access
server. For more information on configuring and managing SLIP ports, refer to the
Network Access Software Management Guide.
Verify Multisessions - Interactive SLIP Connection Only
If you are unable to connect to a SLIP host, enter the following command. Substitute the
port number for 1:
Local> SHOW PORT 1
Verify that Multisessions is Disabled. (If Disabled, Multisessions does not appear in the
list under Enabled Characteristics.) For more information on configuring and managing
SLIP ports, refer to the Network Access Software Management Guide.
Verify Port Configuration - Dedicated SLIP Connection Only
If you are having problems connecting to a device, such as a computer or PC configured as
a dedicated SLIP host, enter the following command. Substitute the port number for 1:
Local> SHOW PORT 1
Port 1: Development S. Server: GEMINI
Character Size: 8 Input Speed: 9600
Flow Control: None Output Speed: 9600
Parity: None Signal Control: Disabled
Stop Bits: Dynamic Signal Select:CTS-DSR-RTS-DTR
Access: Local Local Switch: None
Backwards Switch: None Name: PORT_1
Break: Disabled Session Limit: 4
Forwards Switch: ‘ Type: Ansi
Default Protocol: SLIP Default Menu: None
Autolink Timer One:10 Two:10 Dialer Script: None
Dedicated Service: SLIP
Authorized Groups: 60, 70
(Current) Groups: 60
Enabled Characteristics:
Autoconnect, Broadcast, Failover,
Loss Notification, Message Codes, SLIP, Verification