Installation guide

Messages 900 999
26-10
Local -965- Dump failed
Explanation: The access server has not been successful in performing a dump. It will try
to perform a dump a number of times before generating this message.
Action: Refer to message 914 for more information.
Local -966- Transmission failure on NI
Explanation: The transmission of a packet has failed on the network interface (NI) due to
a physical layer problem.
Action: Press Ctrl/P on the console terminal to perform a self-test.
If a fault is detected, messages 941 and 952 are generated. Refer to those messages for
additional information.
If a fault is not detected, wait for message 953. If message 966 accompanies message
953, forward message 966, together with the sequence of events following self-test, to
your system manager. Otherwise, refer to message 953 for additional information.
Local -967- Parameter checksum error detected in NVRAM
Explanation: The self-test has detected a checksum error in nonvolatile random-access
memory (NVRAM).
Action: Reset the access server to its factory settings. If this fails to correct the problem,
refer to Chapter 29 for service information.
Local -969- Requesting type Software - software-id
Explanation: The access server is requesting software for a downline load. If type is
specified, the software requested is identified by software-id. If type is not specified, the
load host chooses the software, and software-id is not displayed.
Action: No user action is required.
Local -970- Specified load failed, retrying with default parameters
Explanation: The load device or image you specified was not found.
Action: No user action is required. The access server will fall back to the normal boot
sequence.
Local -991- LOAD channel set to ThinWire
Explanation: The software load channel was set to ThinWire.
Action: No action is required