Installation guide
Messages 900 – 999
26-2
Local -903- [protocol] Loading from host address
Explanation: This message indicates that the load host is downline loading the access
server software. This message is displayed during the initialization process.
Action: No user action is required.
Local -904- Image load complete
Explanation: The software has been successfully downline loaded.
Action: No user action is required.
Local -906- [protocol] Dumping to host address
Explanation: The access server hardware detected an internal fatal error, called a fatal
bugcheck error. This error is caused by either the software or the hardware:
• If the fatal error is a software problem, it is likely to cause only intermittent fatal
bugcheck errors. Your unit might operate again for a period of time, then fail again. If
there is more than one access server on the Ethernet, the problem could affect all the
units.
• If the fatal error is a hardware problem, it is probably isolated to one access server. The
hardware problem may be intermittent and only affect the unit occasionally. There is
no corrective procedure for this problem. Refer to Chapter 29 for service information.
When a fatal bugcheck error occurs, the access server attempts an upline dump of its
memory to a load host on the Ethernet. If several load hosts are defined, the address of the
one that accepted the upline dump can be determined using the SHOW SERVER STATUS
command. The Ethernet address of the dump host is displayed along with crash
information from the fatal bugcheck error message.
Action: Record the values of the five parameters displayed in message 913, and forward
this information and the access server upline dump file to your supplier. Refer to Chapter
29 for service information.
Local -907- Image dump complete
Explanation: The access server has terminated abnormally. It has completed an upline
dump and the self-test code is taking control of the access server.
Action: Forward the access server upline dump file to your supplier. Refer to Chapter 29
for service information.
Local -909- Requesting software update of Flash RAM
Explanation: This is a firmware status message indicating a pending update of Flash
RAM. System initialization will take longer than normal.
Action: No user action is required.