Installation guide
Messages 700 – 799
24-8
Explanation: The problem might be caused by one of the following:
• You did not specify a port number (you cannot loop back to your own port).
• You specified a port that is under session management control.
• The two ports are operating at different input and output speeds.
Local -733- Port n already under test
Explanation: You entered the TEST PORT command for a port that is already being
tested. Only one port test can be active at a time.
Action: Wait until the test has finished or use another port.
Local -734- Invalid operation from a remote management console
Explanation: You entered an invalid command from the remote console port.
Action: Specify a port number when entering the SET and SHOW commands from the
remote console port.
Local -735- Service service-name does not support requested test
Explanation: The service or service node that you requested in a TEST SERVICE
command does not support the specified test.
Action: No user action is required.
Local -736- Parameter cannot be modified by a DEFINE or CHANGE com-mand
Explanation: You tried to use the DEFINE or CHANGE command to modify a
characteristic that cannot be modified in the permanent database.
Action: Use the SET command to modify the characteristic.
Step Action
1 Ensure that you have specified a port number other than your own.
2 Disable session management on the port or use another port.
3 If the two ports are operating at different speeds, change them to be consistent with
each other. For more information on the TEST PORT LOOPBACK command, refer to
the Network Access Software Commands Reference Guide.