Messages 600 – 699
23-4
Local -612- Flash RAM write protected
Explanation: For network access servers with user-installable Flash RAM cards, this
message indicates that the card installed has its write-protect switch in the protected
position.
Action: Set the switch to the write-enabled position.
Local -613- Flash RAM erase failure
Explanation: The Flash RAM failed verification of one or more erase cycles.
Action: Retry the update. If it fails again, replace the defective Flash RAM card.
Local -614- Flash RAM illegal address used
Explanation: An internal software error has occurred.
Action: Contact your authorized service representative.
Local -615- Flash RAM invalid boot block detected
Explanation: The Flash RAM card either was not previously programmed or was left in
an inconsistent state of programming. The access server software has attempted to format
the Flash RAM by writing a valid but empty boot block.
Action: This action does not require that a Flash RAM update command has been issued.
If this message is accompanied by other Flash RAM error messages, the Flash RAM
device may be defective.