Installation guide

19-1
Chapter 19
Messages 200 299
Overview
Introduction
This chapter provides information on messages 200 299.
Messages
Local -201- Connection to service-name not established
No response within timeout period
Explanation: The connection request failed or the existing connection was terminated
because the retransmit limit on the circuit has been reached. When the retransmit limit is
reached, the circuit between the access server and the service node is terminated.
Action: Verify the LAT service configuration (Chapter 2).
Local -202- Connection to service-name not established
Communication protocol error
Explanation: The access server is receiving messages that violate the LAT protocol.
Step Action
1 Try to reconnect to the service.
2 If the connection fails, reinitialize the access server to downline load the software.
3 Verify that the access server is running the latest software.
4 Try to reconnect to the service.
5 If the error messages reappear, you might have a software problem.