Installation guide

10-5
Terminal and Personal Computer Problems
Local> SHOW PORT 1
Port 1: Michael Server: GEMINI
Character Size: 8 Input Speed: 9600
Flow Control: XON Output Speed: 9600
Parity: None Signal Control: Disabled
Stop Bits: Dynamic Signal Select: CTS-DSR-RTS-DTR
Access: Local Local Switch: ^^
Backwards Switch: None Name: PORT_1
Break: Local Session Limit: 8
Forwards Switch: Type: Ansi
Default Protocol: LAT Default Menu: None
Autolink Timer One:10 Two:10 Dialer Script: None
Preferred Service: GALAXY
Authorized Groups: 60, 70, 80
(Current) Groups: 60, 70, 80
Enabled Characteristics:
Autobaud, Autoconnect, Autoprompt, Broadcast, Input Flow
Control, Loss Notification, Message Codes, Multisessions,
Output Flow Control, Verification
Flow Control ensures that characters are not lost because of insufficient buffer space at the
access server port or port device. You can set up the XON/XOFF characters as flow
control characters. You can also specify that the DSR/DTR or CTS/RTS signals
implement flow control. Be sure that the flow control characters or signals you choose for
the access server port are also enabled on the terminal. For more information on flow
control, refer to the Network Access Software Management Guide.