Specifications

Enterprise Alarm Manager
Known Alarm Manager Anomalies in SPECTRUM 6.5
SPECTRUM Software Release Notice Page 29
2. A selected alarm prints blackened out without being able to read it.
3. The probable cause column title bleeds through the scroll bar on the
Windows NT printout.
Solution: These printouts require that you use a Level 2 Postscript
printer which eliminates the printing problems.
Problem 4: Currently, alarm IDs may not be unique during a single
runtime session of SpectroSERVER. One possible outcome could be when
you attempt to clear one alarm, a different alarm is cleared instead.
Solution: The chance that this problem will occur is very low. This
problem will be corrected in a future release of SPECTRUM.
Problem 5: When you filter by Probable Cause ID, everything is filtered
out. When you toggle the filter to Search and you set the button to
Probable Cause ID, no alarms are selected.
Solution: Paste the entire ID into the field instead of typing it one
character at a time. This problem will be addressed in a future release of
SPECTRUM.
Problem 6: In Alarm Manager, when a person’s name (as opposed to a
valid email address or username) is entered in the Troubleshooter/Name
field, mail in Alarm Notifier will fail when it is sent to that person.
Solution: Enter either the person’s email address or username as the
Troubleshooter Name when entering Troubleshooter information. It can be
the same as the email address entered in the email address field. This
problem will be corrected in a future release of SPECTRUM.
Problem 7: The Enterprise Alarm Manager view resizes itself after you
maximize the window, open the View menu, and select Show Toolbar. It
will also resize itself after you open the View menu, and choose Show
Filter/Search Panel.
Solution: This problem will be corrected in a future release of
SPECTRUM.