only happens with some SmartSwitch 9000 modules; for example; the
9E133-36, 9E138-36, 9E423-24, and 9F310-02 SmartSwitch models
display the following:
Update failed for the following attributes:
Attribute 0x1194c - Attribute doesn’t exist on
device,0x200000a
Solution: In order for the Static Bridging Table to work correctly, a
“MacAddr.receiveport” entry must be provided. Then, click the Create
Static Database Entry, confirm the”MacAddr.receive” value’s existence,
click Close, and click Save again. This saves the MAC address as a Static
Database Entry, and the error message will not appear.
Problem 5: For the 9T125_08 and 9T122_24, the CsTRing1App’s
Cabletron Token Ring Configuration View shows ?? within the Beacon
State field.
Solution: This is a firmware problem.
Problem 6: You may have difficulty creating (and removing) PVCs and
PVPs from SmartCell, 9A656_04, and 9A686_04 devices.
Solution: Use the Virtual Channel views available for your device to
create PVCs, and the Virtual Path views to create PVPs. The creation
procedures are the same. Creating a PVC involves defining individual links
(VPI/VCI) on each of two ports and then cross connecting the ports. You
use a virtual channel link view to define the links on each port and then
use a cross connect view to cross connect the ports. Check the following
before you begin: you must have write privileges for the device; the traffic
parameters for the ports must be set properly; and the ILMI parameters
must be set. (Use local management to do this.) The following summarizes
the creation procedure using a Zeitnet device. The procedure will be similar
for the other devices.
1 In a Virtual Channel Link view, set the link information (IF Index, VPI,
and VCI). For example, 20101.0.160.