Specifications
Corrected & Known Anomalies
SPECTRUM Software Release Notice Page 160
Common Anomalies - SmartSwitch 9000/9500
The following affect two or more Management Modules and the associated
devices.
Corrected Anomalies:
1 The port interfaces in Device Topology and Device views now appear
after modeling a 9E312_12 device. Twelve interface ports appear in
the views. Also, the Model Information view no longer displays the
model state value as "Error."
Known Anomalies:
Problem 1: Currently, you can create SmartSwitch 9000 models in
Location or Organization views, even though a Contains relation cannot be
established with the SmartSwitch chassis model, and the models do not
show up in the Device view of the SmartSwitch.
Solution: Do not create any SmartSwitch 9000 models in the Location or
Organization views; instead create the model in the Topology view and then
copy the device icon from the Universe Topology view into the Location
view. The SmartSwitch chassis model has a Container view which contains
Location view icons for all modeled SmartSwitch modules. This ensures
that the proper relationship between the models exists.
Problem 2: 9E42x-x and 9H42x-xx device Transparent Bridging Port
tables show no MIB-II Interface statistic for INB interfaces for Port In
Frames, Port Out Frames, and Port In Discards.
Solution: This will be addressed in a future release.
Problem 3: When modeling a 9A6x6 as a standalone, the Chassis Device
view incorrectly displays the backplane interfaces.
Solution: This is a firmware issue; upgrade to firmware 3.00.04 or later.
Problem 4: Error messages may appear when you attempt to save created
entries within the Static Bridging application’s Static Bridging Table. This