Specifications

Corrected & Known Anomalies
SPECTRUM Software Release Notice Page 119
Problem 4: For SwCat1200 models, double-clicking any interface’s IF
Status label displays the Interface Status view with a red-boxed Port Oper
Status field.
Solution: For switches with firmware versions not supporting the
trunking status attribute, Port Oper Status will be red-boxed.
Problem 5: In the Device Topology view of the SwCat5505, reconfigured
(swapped) boards appear in incorrect numeric order.
Solution: The port information is correct. This is a firmware problem;
SPECTRUM reads the incorrect CATStackMib MIB values and therefore
cannot reorganize or update the interfaces in a logical order.
Problem 6: The Catalyst 8500 does not display CAT_IF_Ports.
Solution: This is a device related issue. The device does not support the
CISCO-STACK-MIB.