Specifications

Enterprise Configuration Manager (ECM)
Known ECM Anomalies in SPECTRUM 6.0.2
SPECTRUM Software Release Notes Page 74
Problem 5: Sometimes the keyboard focus is lost. For example, you may
not be able to edit the value of a configuration in the Configurations
window.
Solution: Move the mouse outside of the window and then bring it back
into the window.
Problem 6: The X window manager may perform unpredictably when you
select attributes from devices that display duplicate attributes. If you
select a range of attributes that includes duplicates, the duplicate
attributes may not remain selected.
Solution: Whenever you are adding or cutting a range of selected
attributes that include duplicates, scan the selected list and make sure
duplicate attributes are selected.
Problem 7: When displaying long attribute values, the Verify Detail
window sometimes truncates the left portion of the display. This may
happen when you scroll to the right in the Verify Detail window, cancel out
of the window, and then re-enter the Verify Detail window.
Solution: Once the truncation has occurred, click on the middle of the
horizontal scroll bar. ECM resets the display so that it is left justified.
Problem 8: The following problem occurs when you select an attribute
that has no attribute value in the Configurations window and then you try
to enter a value for the attribute in the Convert dialog box. When you enter
the value and then press OK or Apply in the Convert dialog box, no value
appears in the Configurations window.
Solution: If an attribute has no value, enter a temporary value in the
Configurations window before you open the Convert dialog box. As long as
there is some value in the attribute value field, ECM will add the new
information from the Convert dialog box.
Problem 9: Some attributes such as AT_Net_Addr are no longer
maintained by the designers of the device. In the MIB, these variables have
the status of “Deprecated.” Attempts to read or write to these attributes will
meet with unpredictable results.