Specifications

Corrected & Current Anomalies
SPECTRUM Software Release Notes Page 188
Problem 2: Opening certain SPECTRUM views may cause link error
messages to appear in the SpectroGRAPH window. These messages will not
affect the operation of SPECTRUM.
Solution: This problem will be addressed in a future release.
Problem 3: Traps are only generated against the IP address of the first
Data Collection Engine (DCE) on an Ethernet or Token Ring Network
Management Module (NMM). If contact is lost with the first DCE, the user
will not receive traps.
Solution: This is a firmware problem.
Problem 4: In the Device view, TR DCE icons may disappear and the NMM
Module menu selections will change to a default (Module Notes and Module
Configuration.)
Solution: This is a firmware problem where the TR NMM is rebooting and
the TR NMM entry disappears from the device’s module table.
Problem 5: Information deleted from the Config File Name and/or Image
File Name fields in the DCE Agent Configuration view reappears in the view
after the view’s next poll cycle.
Solution: Replace the entries to be deleted with null characters or blank
spaces. This is a firmware problem.
Problem 6: In the Ring In/Ring Out Extension Information view, the Ring
In UNA and the Ring Out UNA may be “0.0.0.0.0.0,” or both values may be
the same.
Solution: This is a firmware problem.
Problem 7: Attempts to change all Module Ring attachments and Module
Ring Speed for all attachments in a TR Module Configuration view fail
when done simultaneously during the editing session.
Solution: Change the Module Ring Attachments first followed by the
Module Ring Speed, or vice versa. Do not attempt to change both at the
same time. This is a firmware problem.